24 Inch Exhaust Fan Motor Winding Data.

24 slot exhaust fan motor winding data

24 Inch 24 slot exhaust fan motor winding data 24 slot 1400 rpm exhaust fan motor 24 slot motor winding diagram 24 INCH EXHAUST FAN MOTOR WINDING DATA 24 slot cooler winding,Here we have shown how to rewind a  24 INCH EXHAUST FAN motor.How much will be its pitch, which will be the number of the wire, how many slots

24 Inch Exhaust Fan Motor Winding Data.

24 Inch Exhaust Fan Motor Winding Data.

24 Inch Exhaust Running Winding Data

  • slot=24
  • Core Length = 1.5 Inch
  • Rpm = 960
  • Running pitch 1=6
  • Running Winding Coil Turn  1-6=330
  •  Running Winding Wire No =30
  • Motor Winding Wire Type = Copper Wire

24 Inch Exhaust Starting Winding Data

  • Starting Coil pitch  1-6
  • Starting Turn    1-6=300
  • Starting swg=30
  • total running coils =6coils
  • total starting coils=6coils
  • Connection =Normal